Table of Contents
ZEDEDA: Third Party Integrations & Data Streams
Step-by-step guide to forwarding edge telemetry from ZEDEDA Cloud to an external observability backend.
A Third Party Integration defines where telemetry goes (a Splunk HEC endpoint or an OpenTelemetry gRPC collector). A Data Stream defines what telemetry is sent (application logs, events, or device metrics) and binds it to an integration. You must create the integration first, then attach one or more data streams to it.
- Captured on UI Version
19.2.9/ API Version19.2.28. - Both features live under the Enterprise scope, so this is enterprise-admin configuration, not per-project.
Media upload: This page references 15 screenshots in the 3rd-party-integrations namespace. Upload all files into that namespace via the Media Manager. If your DokuWiki install rewrites hyphens to underscores on upload, adjust the 3rd-party-integrations references to match.
Prerequisites
- An enterprise account with admin rights to the Enterprise menu.
- Endpoint details for your backend (host, port, and an auth token).
- For Splunk: an HTTP Event Collector (HEC) token and the HEC URL path.
- For OpenTelemetry: an OTLP/gRPC endpoint and a bearer token.
Part 1 — Create a Third Party Integration
Step 1.1 — Open Third Party Integrations
Step 1.2 — Add Integration
Step 1.3 — Choose Category and Type
Give the integration a Name, then pick the Integration Category. Two categories are available: Data and Remote Orchestration. For log/event/metric forwarding, choose Data.
Then pick the Integration Type. For the Data category the available types are Splunk and OpenTelemetry (gRPC).
Step 1.4a — OpenTelemetry (gRPC) integration
Fill in the OpenTelemetry fields and click Add.
| Field | Example value | Notes |
|---|---|---|
| Name | MC-OTEL | Friendly label referenced later by Data Streams |
| Integration Category | Data | |
| Integration Type | OpenTelemetry (gRPC) | |
| Bearer Token | abcd2334…c801b | Auth credential sent to the collector |
| Skip Verify | On | Skip TLS certificate verification |
| Enable TLS | On | Use TLS for the gRPC connection |
| Host | your.otel.url | OTLP/gRPC collector hostname |
| Port | 4317 | Default OTLP/gRPC port |
Step 1.4b — Splunk integration
Alternatively, fill in the Splunk fields and click Add.
| Field | Example value | Notes |
|---|---|---|
| Name | MC-SPLUNK | |
| Integration Category | Data | |
| Integration Type | Splunk | |
| HTTP Event Collector Token | abcd1234…c801b7 | Splunk HEC token |
| Skip Verify | On | Skip TLS certificate verification |
| Enable TLS | On | Use TLS for the HEC connection |
| Host | your.splunk.url | Splunk HEC host |
| Port | 8088 | Default Splunk HEC port |
| URL Extension | services/collector/event | HEC event endpoint path |
Step 1.5 — Verify the integrations
The panel now shows each integration as a card with its Name, Category, and Type, plus a status badge.
- Verified (green check): the platform has confirmed connectivity to the endpoint (MC-SPLUNK above).
- Initialized (amber triangle): the integration has been created but is not yet confirmed/verified (MC-OTEL above).
- Use the trash icon on a card to delete an integration.
Part 2 — Create Data Streams
Step 2.1 — Open Data Streams
Step 2.2 — Add Data Stream
Step 2.3 — Choose a Data Streaming Type
Open Data Streaming Type. Three telemetry categories are available:
| Type | Sends |
|---|---|
| Application Logs Streaming | Logs from edge applications |
| Events Streaming | Platform / device events |
| Device Metrics | Edge node telemetry metrics |
Step 2.4 — Bind to an integration
Set the Name, leave Enable Streaming on, then select a Third Party Integration. The dropdown lists the integrations created in Part 1.
Step 2.5 — Example: three streams to MC-OTEL
Create one stream per telemetry type, all pointing at the same integration.
Application Logs → MC-OTEL (name MC-OTEL-STREAM):
Events → MC-OTEL (name MC-EVENT-STREAM):
Device Metrics → MC-OTEL (name MC-DEVICE-METRICS):
- Repeat the same three types against
MC-SPLUNKto fan telemetry out to both backends.
Step 2.6 — Review all data streams
Each stream shows its Name, Type, target Integration, and a green Streaming badge when active.
| Name | Type | Integration |
|---|---|---|
| SPLUNK-STREAM-LOGS | Application Logs Streaming | MC-SPLUNK |
| SPLUNK-EVENTS | Events Streaming | MC-SPLUNK |
| SPLUNK-DEVICE-METRICS | Device Metrics | MC-SPLUNK |
| MC-OTEL-STREAM | Application Logs Streaming | MC-OTEL |
| MC-EVENT-STREAM | Events Streaming | MC-OTEL |
| MC-DEVICE-METRICS | Device Metrics | MC-OTEL |
Notes
- Create the integration before the data stream; the stream's Third Party Integration dropdown only lists existing integrations.
- You can stream all three telemetry types to the same integration, and to more than one integration in parallel.
- The Enable Streaming toggle lets you pause a stream without deleting it.
- Default ports: Splunk HEC
8088, OTLP/gRPC4317.
Reference
- ZEDEDA Help: https://help.zededa.com